MODIFIED LINEAR SCANNING ALGORITHMS IN COMPUTED TOMOGRAPHY

Authors

DOI:

https://doi.org/10.17721/3041-1491/2024.11-43

Keywords:

computed tomography, cone-beam, medical diagnostics, three-dimensional reconstruction

Abstract

Introduction. This paper investigates and analyzes the effectiveness of a new approach to computed tomography, based on cone-beam tomography using a linear trajectory of the radiation source. Standard approximate reconstruction methods, despite their speed, can lead to a decrease in image quality, which is critical for diagnostics, such as detecting small-sized tumors at early stages.

Methods. The proposed approach is based on exact reconstruction methods, where the projection data obtained from such scanning geometry is complete, allowing for an accurate and high-quality reconstruction of the object. However, the practical application of such scanning geometry has certain drawbacks and limitations, so several possible modifications of the algorithm are proposed.

Results. Additionally, the paper presents the results of a study on the effectiveness of image reconstruction methods based on simulations of different scanning scenarios. The results indicate high reconstruction accuracy when using a square-closed trajectory with a limited path length of the radiation source.

Conclusions. An analytical reconstruction algorithm was developed and compared with the classical Feldkamp-Davis-Kress (FDK) algorithm. The results showed that the new algorithm provides more accurate reconstruction and faster data processing, which will contribute to improving diagnostic procedures in medical practice.

 

References

Bulavin, L., Zabashta, Y., Motolyha, O., & Senchurov, S. (2017). Analysis of stability of tomographic reconstruction of X-ray medical images. Biofizychnyi Visnyk Biophysical Bulletin, 37(1), 9–15 [in Ukrainian]. https://doi.org/10.26565/2075-3810-2017-37-02

 

Fu, Z., Tseng, H.W., & Vedantham, S. (2024). An attenuation field network for dedicated cone beam breast CT with short scan and offset detector geometry. Scientific Reports, 14, 319. https://doi.org/10.1038/s41598-023-51077-1

 

Haltmeier, M. (2014). Exact reconstruction formulas for a Radon transform over cones. Inverse Problems, 30(3), 035001. https://doi.org/10.1088/0266-5611/30/3/035001

 

Smith, B.D. (1990). Cone-beam tomography: recent advances and a tutorial review. Optical Engineering, 29(5), 524–534. https://doi.org/10.1117/12.55621

 

Tao, B., Shen, Y., Sun, Y., Huang, W., Wang, F., & Wu, Y. (2020). Comparative accuracy of cone‐beam CT and conventional multislice computed tomography for real‐time navigation in zygomatic implant surgery. Clinical Implant Dentistry and Related Research, 22(6), 747–755. https://doi.org/10.1111/cid.12958

 

Weiwen, W., Chao, Q., & Fenglin, L. (2016). Filtered Back-Projection Image Reconstruction Algorithm for opposite parallel linear CT scanning. Acta Optica Sinica, 36(9), 0911009. https://doi.org/10.3788/aos201636.0911009

 

Withers, P.J., Bouman, C., Carmignato, S., Cnudde, V., Grimaldi, D., Hagen, C.K., Maire, É., Manley, M., Du Plessis, A., & Stock, S.R. (2021). X-ray computed tomography. Nature Reviews Methods Primers, 1, 18. https://doi.org/10.1038/s43586-021-00015-4